Model NO.: NH1/NT1
Operation: Electric Type
Installation: Insert
Speed: High-Speed Circuit Breaker
Structure: Conventional Circuit Breaker
Arc-Extinguishing Medium: Quartz Sand
Function: Overcurrent Protection
Certification: Ce
Trademark: SR
Transport Package: Carton
Specification: CE, IEC, ISO
Origin: Zhejiang, China
HS Code: 8536100000
NT Low Voltage Fuse and BaseApplication
NT low voltage H. R. C. Fuse is light in weight, small in size, low in power, loss and high in breaking capacity. This product has been widely used in overload and short circuit protection of electric installations.
This product conforms to IEC 269 and VDE0636 standards with all of the rating at the world advanced level.
Type | Fuse Link | Fuse Base | |||||
Rated Current (A) Â |
Rated Voltage (V) Â |
Rated Power Loss(W) Â |
Weight (Kg) Â |
Type |
Rated Current (A) Â |
Weight (Kg) Â |
|
RT16-000/NT00C Â |
2 | 500,690 | 0.41 | 0.15 | Sist101 | 160 | 0.2 |
4 | 0.62 Â | ||||||
6 | 0.81 | ||||||
10 | 1.08 | ||||||
16 | 1.60 | ||||||
20 | 1.81 | ||||||
25 | 2.31 | ||||||
32 | 3.07 | ||||||
36 | 3.17 | ||||||
40 | 4.05 | ||||||
50 | 4.25 | ||||||
63 | 4.70 | ||||||
80 | 5.7 | ||||||
100 | 7 | ||||||
RT16-00/NT0 | 10 | 500,690 | 1.42 | 0.2 | Sist101 | 160 | 0.32 |
16 | 2.45 | ||||||
20 | 2.36 | ||||||
25 | 2.7 | ||||||
32 | 3.74 | ||||||
35 | 4.3 | ||||||
40 | 4.7 | ||||||
50 | 5.5 | ||||||
63 | 6.9 | ||||||
80 | 7.6 | ||||||
100 | 8.9 | ||||||
125 | 500 | 10.1 | |||||
160 | 15.2 | ||||||
RT16-1/NT1 | 80 | 500,690 | 6.2 | 0.36 | Sist201 | 250 | 0.8 |
100 | 7.5 | ||||||
125 | 10.2 | ||||||
160 | 13 | ||||||
200 | 15.2 | ||||||
224 | 500 | 16.8 | |||||
250 | 18.3 | ||||||
RT16-2/NT2 | 125 | 500,690 | 6.9 | 0.65 | Sist401 | 400 | 1.2 |
160 | 11.5 | ||||||
200 | 15 | ||||||
224 | 16.6 | ||||||
250 | 18.4 | ||||||
300 | 21 | ||||||
315 | 19.2 | ||||||
355 | 24.5 | ||||||
400 | 26 | ||||||
415 | 21.7 | ||||||
RT16-3/NT3 | 355 | 500,690 | 22.7 | 0.85 | Sist601 | 630 | 1.5 |
400 | 26.8 | ||||||
425 | 28.9 | ||||||
500 | 500 | 32 | |||||
630 | 40.3 | ||||||
RT16-4/NT4 | 800 | 380 | 62 | 1.95 | Sist1001 | 1000 | 3.45 |
1000 | 75 |

Wire harness and the surrounding parts shall be even and sufficient distance shall be kept from the heat source,
Considering the protection against electromagnetic interferencee,
Consider assembly technology, maintenance technology,
Grounding wire layout,
Heat dissipation of wire harness and fuse box
Car Seat Harness,Power Seat Wiring Harness,Power Seat Harness,Right Seat Wire Harness
Dongguan YAC Electric Co,. LTD. , https://www.yacentercns.com