Siemens brand
6SE70 book type inverter: When the setting password cannot be opened, the data in P358 and P359 can be changed to the same.
ABB brand
ACS600 inverter: Enter the password "23032" in the 16.03 parameter, and set the parameter 102.01 to false to enter all the main control board parameters.
Mitsubishi brand
740 series inverter: When the setting password cannot be opened, unplug the panel and plug it in.
Emerson brand
TD3000: When the password is not set, enter the password 8888.
Yaskawa brand
Yaskawa G5 inverter: The password is displayed in A1-04, adjust to this parameter, and then press and hold the MENU button and RESET button for 10 seconds, you can see the password. Then adjust to A1-05 and enter the password to modify the parameters. Yaskawa G7 inverter: When A1-04 is displayed, press RESET while pressing MENU to display the password setting of A1-05, and then input this password to A1-04.
European brand
590 inverter: The universal password is 131122.
Schneider brand
After setting the password, find the COD in the SUP menu and enter 6969.
Fuji brand
VG5 inverter: The password is the last parameter of the 200th, set to 0 data can not be changed, set to 1 data can be changed. VG7 inverter: Universal password FFFF, that is, you need to lose FFFF to power on.
Hitachi brand
J300 inverter: It is necessary to rename a multi-function terminal to the “initialization†function (parameters C0-C7), then short-circuit this terminal with the common terminal “CM1†(or P24), and then turn off the inverter and then send power. can. To change terminal "7" to "initialize" function, set parameter C6 to "7".
Panasonic brand
Panasonic VFO Inverter: Press MODE three times to press â–² until 999 is displayed. Press â–² and â–¼ and then press SET to reset the password.
LS brand
LG-iS5 inverter: When FU2-94 is set to 240, you can see the MAK parameters.
Delta brand
B series inverter: The super password is 57522. H series inverter: Super password is 33582. S1 series inverter: The super password is 575222. A series inverter: Press MODE and RESET together to display P256, press ENTER to modify this parameter, change 00 to 01, press ENTER to exit and modify all parameters.
Yingweiteng brand
CHV, CHE, CHF series inverter: Super password is 50112.
Sancha brand
The password is set and the parameter CD900 is set to 36521.
Huichuan brand
The super password is 18181.
TECO brand
M3 series inverter: Change the parameter P00 to 05 to see 65 parameters, P00 to 08 for 2-wire initialization, P00 to 03 parameter.
Ou Rui (formerly known as Huifeng) brand
The super password is: 1888.
Pu Chuan Brand
PI2000 inverter: (1) Set C01 to 222 to enter P14; (2) Set P14 to 3 to refresh the CPU. At this time, display PI2000 to set C01 to 222 to enter P14 parameter setting, P14 is set to 2, P01 is Set the model to G, F, P02 to set the inverter voltage 380V, P03 set the inverter rated current, P04 set voltage display, P05 set current display.
Xilin brand
The super password is 6860.
Schwab brand
TX-4T040C type inverter: F00 is the user password setting, the factory setting is: 8888. If the password of the machine has been modified, the method of unlocking the password is: the inverter is powered on, and the JP4 solder joint is shorted, and the factory password is restored. JP4 is above the motherboard CPU, it is an empty terminal, there is no plug, just two pads. After shorting it, enter the parameter setting and confirm the 8888 factory password, you can modify the parameters after F00.